Orient New Life Medical Co.,Ltd.

Orient New Life Medical Co.,Ltd. Quality is life.

Manufacturer from China
Active Member
8 Years
Home / Products / Drug Abuse Test Kit /

Drug Abuse Test Kit Tropicamide Rapid Test strip cut off 350ng/ml

Contact Now
Orient New Life Medical Co.,Ltd.
City:ningbo
Province/State:zhejiang
Contact Person:MrJerry Meng
Contact Now

Drug Abuse Test Kit Tropicamide Rapid Test strip cut off 350ng/ml

Ask Latest Price
Video Channel
Brand Name :New Life
Model Number :TROP STRIP
Certification :ISO13485, CE
Place of Origin :China
MOQ :5000pcs
Price :USD0.5-USD5
Payment Terms :T/T, Western Union
Supply Ability :2000000pcs/month
Delivery Time :20-30days
Packaging Details :1pc/pouch, 25pcs/box
Category :Drug Abuse TESGTING kits
Format :STRIP TROP 3mm
Specimen :Urine
Testing time :5 minu
Shelf Life :24 Months
application :TROP drug test strip
cut-off :300ng/ml
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Drug Abuse Test Kit Tropicamide Rapid Test strip, high sensitivity cut-off 350ng/ml

Product Name

TROP ( Tropicamide) Rapid Diagnostic Test

Specimen: Urine

Background

Tropicamide is an antimuscarinic drug usually prescribed as an ophthalmic solution to induce short-term mydriasis and cycloplegia.

Tropicamide is currently abused (injected intravenously) as an inexpensive recreational deliriant drug1.

Misuse of tropicamide typically occurs through IV injection; its effects last from 30 min to 6 h, and It is usually mixed with heroin, methadone, and other opioid drugs to potentiate the " rush" when injected intravenously2.Medical effects of tropicamide misuse include slurred speech, persistent mydriasis, unconsciousness/unresponsiveness, hallucinations, kidney pain, dysphoria, “open eye dreams,” hyperthermia, tremors, suicidal feelings, convulsions, psychomotor agitation, tachycardia and headache.

The TRO Rapid Test panel (Urine) is a rapid urine screening test that can be performed without the use of an instrument. The test utilizes a monoclonal antibody to selectively detect elevated levels of Tropicamide in urine. The TRO Rapid Test Panel (Urine) yields a positive result when Tropicamide in urine exceeds 350 ng/mL.

Test Principle

The TRO Rapid Test Panel (Urine) is an immunoassay based on the principle of competitive binding. Drugs which may be present in the urine specimen compete against the drug conjugate for binding sites on the antibody.

During testing, a urine specimen migrates upward by capillary action. Tropicamide, if present in the urine specimen below the cut-off level, will not saturate the binding sites of the antibody in the test. The antibody coated particles will then be captured by immobilized Tropicamide-protein conjugate and a visible colored line will show up in the test line region. The colored line will not form in the test line region if the Tropicamide level exceeds the cut-off level, because it will saturate all the binding sites of anti- Tropicamide antibody.

A drug-positive urine specimen will not generate a colored line in the test line region because of drug competition, while a drug-negative urine specimen or a specimen containing a drug concentration less than the cut-off will generate a line in the test line region. To serve as a procedural control, a colored line will always appear at the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred.

SPECIMEN COLLECTION AND STORAGE

The urine specimen must be collected in a clean and dry container. Urine collected at any time of the day may be used. Urine specimens exhibiting visible particles should be centrifuged, filtered, or allowed to settle to obtain clear specimen for testing. Specimen.

Urine specimens may be stored at 2-8°C for up to 48 hours prior to testing. For long-term storage, specimens may be frozen and stored below -20°C. Frozen specimens should be thawed and mixed before testing.

STORAGE

Store as packaged in the sealed pouch either at room temperature or refrigerated (2-30°C). The test is stable through the expiration date printed on the sealed pouch. The test must remain in the sealed pouch until use. DO NOT FREEZE. Do not use beyond the expiration date.

LIMITATION

1. The 6-MAM Rapid Test Cassette provides only a qualitative, preliminary analytical result. A secondary analytical method must be used to obtain a confirmed result. Gas chromatography/mass spectrophotometry (GC/MS) is the preferred confirmatory method2.3.

2. It is possible that technical or procedural errors, as well as other interfering substances in the urine specimen may cause erroneous results.

3. Adulterants, such as bleach and/or alum, in urine specimens may produce erroneous results regardless of the analytical method used. If adulteration is suspected, the test should be repeated with another urine specimen.

4. A positive result indicates presence of the drug or its metabolites but does not indicate level of intoxication, administration route or concentration in urine.

5. A negative result may not necessarily indicate drug-free urine. Negative results can be obtained when drug is present but below the cut-off level of the test.

performance characteristics

A side-by-side comparison was conducted using the Rapid Test Cassette (Urine) and GC/MS. The following results were tabulated:

Tropicamide Percent of Cut-off n Visual Result
Concentration (ng/ml) Negative Positive
0 0 30 30 0
175 -50% 30 30 0
262.5 -25% 30 27 3
350 Cut-off 30 15 15
437.5 +25% 30 3 27
525 +50% 30 0 30
1050 3X 30 0 30


Drug Abuse Test Kit Tropicamide Rapid Test strip cut off 350ng/ml

ORIENT NEW LIFE MEDICAL CO., LTD.
Contact: Jerry Meng
Email: Jerry @ newlifebiotest .com
Tel. +86 18657312116
SKYPE enetjerry
Inquiry Cart 0