Orient New Life Medical Co.,Ltd.

Orient New Life Medical Co.,Ltd. Quality is life.

Manufacturer from China
Active Member
8 Years
Home / Products / Drug Abuse Test Kit /

Drug Abuse Test Kit K2 (Synthetic Marijuana) Rapid Diagnostic Test strip, professional use, urine drug test, 50ng/ml

Contact Now
Orient New Life Medical Co.,Ltd.
City:ningbo
Province/State:zhejiang
Contact Person:MrJerry Meng
Contact Now

Drug Abuse Test Kit K2 (Synthetic Marijuana) Rapid Diagnostic Test strip, professional use, urine drug test, 50ng/ml

Ask Latest Price
Video Channel
Brand Name :New Life
Model Number :dipcard
Certification :ISO13485, CE
Place of Origin :China
MOQ :5000pcs
Price :USD0.5-USD5
Payment Terms :T/T, Western Union
Supply Ability :2000000pcs/month
Delivery Time :20-30days
Packaging Details :1pc/pouch, 25pcs/box
Category :Drug Abuse test kit
Format :strip
Specimen :Urine
Testing time :5-15 minutes
Shelf Life :24 Months
application :K2
cut-off :50ng/ml
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Drug Abuse Test Kit K2 (Synthetic Marijuana) Rapid Diagnostic Test strip, professional use, urine drug test, 50ng/ml


Product Name

K2 (Synthetic Marijuana) Rapid Diagnostic Test Strip
Specimen: Urine

ProductCat NoSpecimenSensitivityFormatKit Size
K2 YD131S3Urine50 ng/mL3mm Strip100T
YD131C44mm Cassette25T




Intended Use

The Synthetic Marijuana (K2) Rapid Test Strip (Urine) is a rapid chromatographic immunoassay for the detection of Synthetic Marijuana metabolite in human urine. The synthetic marijuana detected by the test includes, but are not limited to, the metabolites of JWH-018 and JWH-073. This assay provides only a preliminary analytical test result. A more specific alternate chemical method must be used in order to obtain a confirmed analytical result. Gas chromatography/mass spectrometry (GC/MS) is the preferred confirmatory method. Clinical consideration and professional judgment should be applied to any drug of abuse test result, particularly when preliminary positive results are used.

ParameterCalibratorCut-off (ng/mL)
K2(Synthetic Marijuana)Synthetic Marijuana50




Test Principle


The K2 Rapid Test Cassette (Urine) is an immunoassay based on the principle of competitive binding. Drugs which may be present in the urine specimen compete against the drug conjugate for binding sites on the antibody. During testing, a urine specimen migrates upward by capillary action. Synthetic Marijuana metabolite, if present in the urine specimen below 50ng/mL, will not saturate the binding sites of antibody-coated particles in the test device. The antibody-coated particles will then be captured by immobilized synthetic marijuana conjugate and a visible colored line will show up in the test line region. The colored line will not form in the test line region if the Synthetic Marijuana metabolite level exceeds 50ng/mL because it will saturate all the binding sites of anti- Synthetic Marijuana antibodies. A drug-positive urine specimen will not generate a colored line in the test line region, while a drug-negative urine specimen or a specimen containing a drug concentration less than the cut-off will generate a line in the test line region. To serve as a procedural control, a colored line will always appear at the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred.


DIRECTIONS FOR USE

  1. Bring the pouch to room temperature before opening it. Remove the Test Dipstick from the sealed pouch and use it within one hour.
  2. With arrows pointing towards the urine specimen, immerse the Test Dipstick vertically in the urine specimen in such a way that urine does not cross MAX line on the Test Dipstick for 10-15 seconds. See the illustration below.
  3. Wait for the color line(s) to appear. The result should be read at 5 minutes. Do not interpret the result after 10 minutes.



INTERPRETATION OF RESULTS


NEGATIVE:* A colored line appears in the Control region (C) and colored lines appears in the Test region (T). This negative result means that the concentrations in the urine sample are below the designated cut-off levels for a particular drug tested.

*NOTE: The shade of the colored lines(s) in the Test region (T) may vary. The result should be considered negative whenever there is even a faint line.

POSITIVE: A colored line appears in the Control region (C) and NO line appears in the Test region (T). The positive result means that the drug concentration in the urine sample is greater than the designated cut-off for a specific drug.

INVALID: No line appears in the Control region (C). Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for Control line failure. Read the directions again and repeat the test with a new test card. If the result is still invalid, contact your manufacturer.




PERFORMANCE:


Accuracy

A side-by-side comparison was conducted using the K2 Rapid Test Dipstick (Urine) and GC/MS. The following results were tabulated:

Method GC/MSTotal Results
K2 Rapid ResultsPositiveNegative
Positive78381
Test Dipstick
Negative2167169
Total Results 80170250
% Agreement 97.5%98.2%98.0%



Analytical Sensitivity


A drug-free urine pool was spiked with K2 at the following concentrations: 0,25,37.5,50,62.5,75 and 150ng/mL. The results demonstrate >99% accuracy at 50% above and 50% below the cut-off concentration. The data are summarized below:

Synthetic MarijuanaPercent ofnVisual Result
Concentration (ng/mL)Cut-offNegativePositive
00%30300
25-50%30300
37.5-25%30264
50Cut-off301515
62.5+25%30327
75+50%30030
1503X30030


ORIENT NEW LIFE MEDICAL CO., LTD.
Contact:Jerry Meng
Email:Jerry @ newlifebiotest .com
Tel.+86 18657312116
SKYPEenetjerry























































Inquiry Cart 0