Orient New Life Medical Co.,Ltd.

Orient New Life Medical Co.,Ltd. Quality is life.

Manufacturer from China
Active Member
8 Years
Home / Products / Cardiac Blood Tests /

One Step H-FABP Cardiac Blood Tests Multiple Cassette Gold Colloidal For Health

Contact Now
Orient New Life Medical Co.,Ltd.
City:ningbo
Province/State:zhejiang
Contact Person:MrJerry Meng
Contact Now

One Step H-FABP Cardiac Blood Tests Multiple Cassette Gold Colloidal For Health

Ask Latest Price
Video Channel
Brand Name :New Life
Model Number :cassette
Certification :ISO13485,CE
Place of Origin :China
MOQ :5000pcs
Payment Terms :T/T, Western Union
Supply Ability :2000000pcs/month
Delivery Time :20-30days
Packaging Details :1pc/pouch, 25pcs/box
Category :Cardiac
Format :4mm multiple
Specimen :Whole Blood/Serum/Plasma
Testing time :5-15 minutes
Shelf Life :24 Months
Application :Acute MI
accurary :98.55%
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

One Step multiple cassette H-FABP/Cardiac Troponin I Combo cardiac blood Tests , gold colloidal method, quickly and easily

Intended Use:

The H-FABP/Cardiac Troponin I Combo Rapid Test Cassette (Whole Blood/Serum/Plasma) is a rapid chromatographic immunoassay for the qualitative detection of human H-FABP and cardiac Troponin I (cTnI) in whole blood, serum or plasma as an aid in the diagnosis of myocardial infarction (MI).

Summary:

FABP is a newly introduced plasma marker of acute myocardial infarction (AMI). The plasma kinetics of FABP (15 kD) closely resemble those of myoglobin in that elevated plasma concentrations are found within 2 hours after AMI and return to normal generally within 18 to 24 hours. But the concentration of FABP in the skeletal muscle is 20 times lower than in cardiac tissue (for myoglobin the same content for cardiac and skeletal tissue), that makes FABP to be more cardiac specific than myoglobin. This makes FABP a useful biochemical marker for the early assessment or exclusion of AMI. FABP also appears to be a useful plasma marker for the estimation of myocardial infarct size. FABP is suitable for use as a standard in immunoassay for early detection of acute myocardial infarction, immunogen for antisera production, mass FABP standard, FABP biochemical and immunochemical studies, tracer for iodination. Cardiac Troponin I (cTnI) is a protein found in cardiac muscle with a molecular weight of 22.5 kDa.1 Troponin I is part of a three subunit complex comprising of Troponin T and Troponin C. Along with tropomyosin, this structural complex forms the main component that regulates the calcium sensitive ATPase activity of actomyosin in striated skeletal and cardiac muscle. After cardiac injury occurs, Troponin I is released into the blood 4-6 hours after the onset of pain. The release pattern of cTnI is similar to CK-MB, but while CK-MB levels return to normal after 72 hours, Troponin I remains elevated for 6-10 days, thus providing for a longer window of detection for cardiac injury. The high specificity of cTnI measurements for the identification of myocardial damage has been demonstrated in conditions such as the perioperative period, after marathon runs, and blunt chest trauma. cTnI release has also been documented in cardiac conditions other than acute myocardial infarction (AMI) such as unstable angina, congestive heart failure, and ischemic damage due to coronary artery bypass surgery. Because of its high specificity and sensitivity in the myocardial tissue, Troponin I has recently become the most preferred biomarker for myocardial infarction. The H-FABP/Cardiac Troponin I Combo Rapid Test Cassette (Whole Blood/Serum/Plasma) is a simple test that utilizes a combination of antibody coated particles and capture reagents to qualitatively detect H-FABP and cardiac Troponin I (cTnI) in whole blood, serum or plasma. The minimum detection level is 8 ng/mL H-FABP and 0.5 ng/mL Troponin I.

Test Principle:

The H-FABP/Cardiac Troponin I Combo Rapid Test Cassette (Whole Blood/Serum/Plasma) is a qualitative, membrane based immunoassay for the detection of H-FABP and cardiac Troponin I (cTnI) in whole blood, serum or plasma. The membrane is pre-coated with specific capture antibodies in each of the test line regions of the test. During testing, the whole blood, serum or plasma specimen reacts with the particle coated with specific antibodies. The mixture migrates upward on the membrane chromatographically by capillary action to react with specific capture reagents on the membrane and generate a colored line. The presence of this colored line in the specific test line region indicates a positive result, while its absence indicates a negative result. To serve as a procedural control, a colored line will always appear in the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred.

TEST PROCEDURE

1. Bring the pouched test device to room temperature(15-30℃) prior to testing. Do not open the pouch until ready

to begin testing.

2. Remove the device from the sealed pouch and lay it on a flat and dry surface.

3. Using the provided pipette, add one drop of fresh specimen to the sample well.

4. Hold the buffer bottle vertically and add 1 drop to the sample well. /If using a pipette, change a new one to avoid cross-contamination. Draw and transfer 2-3 drops of buffer to the sample well.

5. Read the result between 15-20minutes. Do not read results after 20 minutes.

Limitation

  1. The H-FABP/Cardiac Troponin I Combo Rapid Test Cassette (Whole Blood/Serum/ Plasma) is for in vitro diagnostic use only. This test should be used for the detection of H-FABP, and cardiac Troponin I (cTnI) in whole blood, serum or plasma specimens only. Neither the quantitative value nor the rate of increase in H-FABP and cardiac Troponin I can be determined by this qualitative test.
  2. The H-FABP/Cardiac Troponin I Combo Rapid Test Cassette (Whole Blood/Serum/ Plasma) will only indicate the qualitative level of H-FABP and Troponin I in the specimen and should not be used as the sole criteria for the diagnosis of myocardial infarction.
  3. The H-FABP/Cardiac Troponin I Combo Rapid Test Cassette (Whole Blood/Serum/Plasma) cannot detect less than 8ng/mL H-FABP and 0.5ng/mL cardiac Troponin I (cTnI) in specimens. A negative result at any time does not preclude the possibility of myocardial infarction.
  4. As with all diagnostic tests, all results must be interpreted together with other clinical information available to the physician.
  5. Some specimens containing unusually high titers of heterophile antibodies or rheumatoid factor (RF) may affect expected results. Even if the test results are positive, further clinical evaluation should be considered with other clinical information available to the physician.
  6. There is a slight possibility that some whole blood specimens with very high viscosity or which have been stored for more than 2 days may not run properly on the test cassette. Repeat the test with a serum or plasma specimen from the same patient using a new test cassette.

One Step H-FABP Cardiac Blood Tests Multiple Cassette Gold Colloidal For Health

One Step H-FABP Cardiac Blood Tests Multiple Cassette Gold Colloidal For Health

PERFORMANCE CHARACTERISTICS

Sensitivity and Specificity

The Cardiac Combo Rapid Test Card has been evaluated with a leading commercial H-FABP/Troponin I EIA test using clinical specimens. The results show that relative to leading EIA test.

H-FABP Test vs. EIA
Method EIA Total
H-FABP Results Positive Negative Results
Positive 54 1 55
Test
Negative 0 422 422
Total Results 54 423 477
Relative Sensitivity: 100% (93.4%-100.0%) *
Relative Specificity: 99.8% (98.7%-99.9%)*
Accuracy: 99.8% (98.8% to 99.9%)* (* 95% Confidence Interval)

Troponin I Test vs. EIA

Method EIA Total
Negativ
Results Positive Results
e
cTnI Test
Positive 225 8 233
Negative 3 505 508
Total Results 228 513 741

Relative Sensitivity: 98.7% (96.2%- 99.7%)*

Relative Specificity: 98.4% (97.0%-99.3%)*

Accuracy: 98.5% (97.4%-99.3%)* (* 95% Confidence Interval)

ORIENT NEW LIFE MEDICAL CO., LTD.
Contact: Jerry Meng
Email: Jerry @ newlifebiotest .com
Tel. +86 18657312116
SKYPE enetjerry
Inquiry Cart 0