Orient New Life Medical Co.,Ltd.

Orient New Life Medical Co.,Ltd. Quality is life.

Manufacturer from China
Active Member
8 Years
Home / Products / Infectious Disease Blood Tests /

One Step Infectious Disease Blood Tests , Legionella Testing Kit Cassette Format

Contact Now
Orient New Life Medical Co.,Ltd.
City:ningbo
Province/State:zhejiang
Contact Person:MrJerry Meng
Contact Now

One Step Infectious Disease Blood Tests , Legionella Testing Kit Cassette Format

Ask Latest Price
Video Channel
Brand Name :New Life
Model Number :Cassette
Certification :ISO13485,CE
Place of Origin :China
MOQ :5000pcs
Payment Terms :T/T, Western Union
Supply Ability :2000000pcs/month
Delivery Time :20-30days
Packaging Details :1pc/pouch, 25pcs/box
Category :Infectious
Format :Strip/cassette
Specimen :Urine
Testing time :5-15 minutes
Shelf Life :24 Months
Application :Legionella pneumophila
Accuracy :88.40%
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

One Step Legionella pneumophila Rapid Diagnostic Test,Gold colloidal method, quickly and easily

Intended Use:

A rapid test for the qualitative detection of Legionella pneumophila antigen in urine specimen.

For professional in vitro diagnostic use only.

TEST PRINCIPLE

The Legionella pneumophila antigen Test Dipstick is a qualitative, lateral flowimmunoassay for the detection ofLegionella pneumophila LPS in urine samples, the membrane is pre-coated with a anti-Legionella antibodies on the test line region ofthe test. During testing, the specimen reacts with the particle coated with anti-Legionella antibodies. The mixture migrates upward on the membrane by capillary action to reactwith anti-Legionella antibodies on the membrane and generate a colored line. Thepresence of this colored line in the test region indicates a positive result, while itsabsence indicates a negative result. To serve as a procedural control, a colored linewill always appear in the control line region indicating that proper volume of specimenhas been added and membrane wicking has occurred.

TEST PROCEDURE

Allow kit components, in unopened packaging, and specimens to reach roomtemperature (15-30°C) before performing a test.

1. Open the pouch and remove the device. Once opened, run the test immediately.

2. Swirl urine gently to mix before testing.

3. With arrows towards pointing toward urine specimen, immerse the test Dipstick vertically in the urine specimen for at least 10-15 seconds. Do not pass the maximum line (MAX) on the test Dipstick when immersing the Dipstick. See illustration below.

4. Place the Dipstick on a non-absorbent flat surface, start the timer and wait for the color line (s) to appear. The result should be read at 15 minutes, do not interpret the result after 20 minutes.

Caution: The above interpreting time is based on room temperature range of 15-30℃. If your room temperature is significantly lower than 15℃, then the interpreting time should be properly increased to 30 minutes.

INTERPRETATION OF RESULTS

Positive:

Two red lines are visible in the result window. The intensity of the test line may be

weaker or darker than that of the control line. This still means a positive result.

Negative:

The control line appears in the result window, but the test line is not visible.

Invalid:

If the control line does not appear in the result window, the test results are INVALID regardless of the presence or absence of the line in the test region.

One Step Infectious Disease Blood Tests , Legionella Testing Kit Cassette Format

PERFORMANCE CHARACTERS:

Sensitivity and Specificity

The kit was evaluated on 189 clinical samples in a National Reference Laboratory in Spain.118 positive urine specimen and 71 negative urine specimen confirmed with the ELISA. Urine samples from patients with respiratory tractinfections other than Legionella infections were tested in a similar manner to test thespecificity of the kit.

Method EIA Total Results
Legionellapneumophila Rapid Test Dipstick (Urine) Result Positive Negative
Positive 97 1 98
Negative 21 70 91
Total Results 118 71 189

Relative sensitivity: 82.2% (95%CI*: 74.1%~88.6%);

Relative specificity:98.6% (95%CI*: 92.4%~99.9%);

Accuracy: 88.4% (95%CI*: 82.9%~92.6%). *Confidence Intervals

NOTE: Insufficient specimen volume or incorrect procedural techniques are the most likely reasons for the control line failure. Review the procedure and repeat the test with a new device. If problem persists, please contact your local distributor.

ORIENT NEW LIFE MEDICAL CO., LTD.
Contact: Jerry Meng
Email: Jerry @ newlifebiotest .com
Tel. +86 18657312116
SKYPE enetjerry
Inquiry Cart 0