Orient New Life Medical Co.,Ltd.

Orient New Life Medical Co.,Ltd. Quality is life.

Manufacturer from China
Active Member
8 Years
Home / Products / Infectious Disease Blood Tests /

High Accuracy Infectious Disease Blood Tests Quick Operation Gold Colloidal

Contact Now
Orient New Life Medical Co.,Ltd.
City:ningbo
Province/State:zhejiang
Contact Person:MrJerry Meng
Contact Now

High Accuracy Infectious Disease Blood Tests Quick Operation Gold Colloidal

Ask Latest Price
Video Channel
Brand Name :New Life
Certification :ISO13485,CE
Place of Origin :China
MOQ :5000pcs
Price :USD0.4-USD1
Payment Terms :T/T, Western Union
Supply Ability :500000pcs/month
Delivery Time :20-30days
Packaging Details :1pc/pouch, 25pcs/box
Category :Tropical disease
Format :Strip/cassette
Specimen :Whole Blood/Serum/Plasma
Testing time :5-15 minutes
Shelf Life :24 Months
Application :Malaria pf/pv
Accuracy :95.63%
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

High Accuracy Malaria pf/pv Rapid Diagnostic test, easily and quick operation, Gold Colloidal method

Product Name:
Malaria P.f & P.v Antigen Test (Cassette)

NTENDED USE: Malaria P.f & P.v Ab test is an immunochromatographic (rapid) test for the qualitative detection of antigen of all specific to Plasmodium falciparum and Plasmodium vivax simultaneously in human serum or plasma or whole blood.

TEST PRINCIPLE

The Malaria P.f./P.v. Rapid Test Device (Whole Blood) is a qualitative, membrane based immunoassay for the detection of P.f and P.v antigens in whole blood. The membrane is pre-coated with anti-HRP-II antibodies and anti-pLDH antibodies. During testing, the whole blood specimen reacts with the dye conjugate, which has been pre -coated on the test strip. The mixture then migrates upward on the membrane by capillary action, reacts with anti-Histidine-Rich Protein II (HRP-II) antibodies on the membrane on P.f Test Line region and with anti-pLDH antibodies on the membrane on P.v. Line region. If the specimen contains HRP-II or Plasmodium-specific P.vivaLDH or both, a colored line will appear in P.f line region or P.v. line region or two colored lines will appear in P.f line region and P.v. line region. The absence of the colored lines in P.f line region or P.v. line region indicates that the specimen does not contain HRP-II and/or Plasmodium- specific P.vivaLDH. To serve as a procedure control, a colored line will always appear in the control line region indicating that proper volume of specimen has been added and membrane wicking has occurred.

TEST PROCEDURE
1. Bring the pouched test device to room temperature(15-30℃) prior to testing. Do not open pouch until ready to perform the assay.
2. Remove the test device from the sealed pouch. Lay it on a flat, clean and dry surface.
3. Use the pipette to draw and slowly add 1 drop of whole blood to the sample well.
4. Hold the buffer bottle vertically and add 1 drop to the sample well. / If using a pipette, change a new one to avoid cross-contamination. Draw and transfer 2-3 drops of buffer to the sample well.
5. Interpret test results within 10-15 minutes. Do not interpret after 20 minutes.
Caution: The above interpreting time is based on room temperature range of 15 - 30°C. If your room temperature is significantly lower than15 °C, then the interpreting time should be properly increased to 30 minutes.

INTERPRETATION OF RESULTS

High Accuracy Infectious Disease Blood Tests Quick Operation Gold Colloidal

Malaria P.f Positive
The control line and Malaria P.f line (T1) are visible in the result window. The test is positive for Malaria P.f.
Malaria P.v Positive
The control line and Malaria P.v line (T2) are visible in the result window. The test is positive for Malaria P.v.
Malaria P.f and Malaria P.v Positive
The control line, Malaria P.f (T1) and Malaria P.v (T2) lines are visible in the result window. The test is positive for Malaria P.f and Malaria P.v.

Negative
The control line is the only line visible in the result window. No Malaria P.f or Malaria P.v has been detected.
Invalid
If the control line does not appear in the result window, the test results are INVALID regardless of the presence or absence of the line in the test region.

Performance Study

Sensitivity

The Malaria P.f./ P.v. Rapid Test Device (Whole Blood) has been tested with microscopy on clinical samples. The results show that the sensitivity of the Malaria P.f./ P.v. Rapid Test Device (Whole Blood) is >98% when compared to results obtained with microscopy.

Specificity

The Malaria P.f./ P.v. Rapid Test Device (Whole Blood) uses antibodies that are highly specific to Malaria P.f.-specific and P.vivaxLDH antigens in whole blood. The results show that the specificity of the Malaria P.f./ P.v. Rapid Test Device (Whole Blood) is over 99.9%, when compared to results obtained with microscopy.

Method MicroscopyTotal
Malaria P.f./ P.v. ResultsPositiveNegativeResults
Rapid Test P. v.P. f.
Positive4980 0129
Device
Negative10 451452
TotalResults5080 451581

Comment: Blood Samples infected by Plasmodium falciparum (n=80).Plasmodium vivax (n=50) were included, as well as 451 malaria negative samples to be confirmed with microscopy.

Relative Sensitivity for P.f.-specific antigens: 80/80> 99.9% (96.4%~100.0%)*

Relative Sensitivity for P.v. antigens: 49/50=98.0% (89.6%~100.0%)*

Relative Specificity: 451/451>99.9% (99.3%~100.0%)*

Accuracy: (49+80+451)/(50+80+451)=580/581=99.8% (99.0%~100.0%)*

* 95% Confidence Interval


Minimum Detection Level
Type Parasites/μl
P. falciparum 200
P.vivax 1500


ORIENT NEW LIFE MEDICAL CO., LTD.
Contact:Jerry Meng
Email:Jerry @ newlifebiotest .com
Tel.+86 18657312116
SKYPEenetjerry







































Inquiry Cart 0